Mechanical equipment is essential to a building’s operation. That does not necessarily mean architects, owners, or municipalities want it to be the first thing people notice.
Architectural screens offer a way to integrate rooftop equipment, parking structures, utilities, and service areas into the overall building design. But screening is about more than improving aesthetics. Depending on the application and jurisdiction, an architectural screen wall may also need to satisfy requirements involving construction materials, fire resistance, structural loads, ventilation, building height, and local zoning.
Understanding those requirements early can help project teams develop equipment screens that complement the building without creating conflicts elsewhere in the design.
Building Code vs. Zoning Code: An Important Distinction
One of the biggest misconceptions about architectural screening is that “code requires equipment to be screened.” Sometimes it does, but the full answer depends on the project.
The adopted building code generally establishes requirements intended to address building construction, structural performance, fire and life safety, and other areas. Local zoning ordinances or development standards may separately require mechanical equipment to be visually concealed or establish standards for where and how screening must occur.
For example, the 2024 International Building Code (IBC) specifically addresses rooftop mechanical equipment screens in Section 1511.6. It establishes requirements for the construction of these assemblies, including provisions related to materials, construction type, fire separation distance, and certain height conditions.
That does not mean every jurisdiction follows the 2024 IBC exactly. States and municipalities adopt and amend model codes on their own schedules. A project team should therefore verify the code edition adopted by the authority having jurisdiction (AHJ) as well as applicable zoning, planning, and architectural requirements.
In other words, compliance should begin with one question: What rules actually apply to this project and location?
Rooftop Equipment Screens Are Part of the Building Design
It can be tempting to think about a rooftop screen late in the project, once the mechanical equipment has already been selected and positioned. From a compliance standpoint, that can create problems.
Section 1511.6 of the 2024 IBC states that mechanical equipment screens are to be constructed from materials specified for exterior walls according to the building’s type of construction. The section also addresses fire-resistance requirements in relation to fire separation distance.
The code goes further for certain construction types. For Type V construction, for example, the 2024 IBC contains specific conditions under which the height of a rooftop mechanical equipment screen can exceed otherwise applicable maximum building height provisions. Those conditions consider factors such as fire separation distance and screen materials.
For architects and contractors, the takeaway is important: an equipment screen cannot always be treated as an independent decorative accessory. Its material, height, location, and construction can interact with the requirements governing the building itself.
Don’t Overlook Wind Loads and Structural Support
A rooftop screen also has to survive where it is installed. Screens can create substantial surfaces exposed to wind. The framing, connections, supports, and building structure therefore need to be designed for applicable loads rather than simply sized to support the screen’s weight.
The Federal Emergency Management Agency (FEMA) notes that inadequate anchorage, insufficient equipment strength, and corrosion can contribute to rooftop equipment being torn from buildings under high-wind conditions. FEMA also identifies ASCE 7 as the referenced standard for wind-load provisions used within the I-Codes. For the 2024 IBC, the applicable referenced edition is ASCE 7-22.
That makes structural coordination especially important for tall or expansive screen walls and screens installed in locations subject to high wind exposure.
Considerations may include:
- Screen height and overall surface area
- Panel openness
- Building height
- Screen location on the roof
- Support framing
- Connections and anchorage
- Applicable design wind loads
- Existing structural capacity
- Corrosion exposure
- Roof penetrations and waterproofing
The exact requirements have to be established by the project’s design professionals using the applicable codes and design criteria.
Screening Can’t Come at the Expense of Equipment Performance
Compliance does not stop at the screen itself. When equipment screens surround HVAC equipment, the design also has to account for the requirements of that equipment. Screens that are too close, too tall, or too restrictive can potentially interfere with the airflow and clearances required for proper operation. That is why openness matters.
Architectural louvers, perforated panels, and other open screening configurations can allow air to move through the screen while reducing direct sightlines to equipment. However, the appropriate percentage of open area cannot be selected based on appearance alone. It depends on the mechanical system, equipment configuration, manufacturer’s requirements, and project design.
Spacing also plays a role in serviceability. Technicians still need appropriate access to inspect, maintain, repair, and potentially replace equipment.
The best screen design therefore asks two questions at the same time:
- What does the building need visually?
- What does the equipment need functionally?
Parking Garage Screening Compliance Considerations
Parking garage screening is a particularly good example of why aesthetics and code analysis must happen together.
An open parking garage may depend on exterior openings for natural ventilation. Under Section 406.5.2 of the 2024 IBC, qualifying open parking garages must have uniformly distributed exterior openings on two or more sides, with the openings representing at least 20% of the total perimeter wall area of each tier. The aggregate length of the openings used for natural ventilation must generally equal at least 40% of the perimeter, subject to an exception for qualifying openings on opposing sides.

Additional IBC provisions rely on prescribed amounts of openness for certain allowable area and height increases. Section 406.5.5, for example, establishes minimum opening criteria for sides considered “open” under those provisions.
That creates an important design consideration. Adding decorative panels, louvers, or perforated screen systems to a parking structure can transform a utilitarian garage into an architectural element, but the screening needs to be evaluated alongside the openness and ventilation provisions applicable to the garage.
A screen that looks open from the street should not automatically be assumed to satisfy the code definition or calculation for an opening.
Make Screens Part of the Plan From the Start
Architectural screens occupy a unique position in building design. They can conceal equipment, transform parking structures, reinforce a building’s visual identity, and help project teams address applicable screening and construction requirements at the same time.
But there is no single equipment screen, perforation pattern, or rooftop configuration that is automatically “code compliant.” Requirements depend on the adopted building code, local amendments, zoning regulations, building construction type, location, structural design, equipment needs, and other project-specific conditions.
Early coordination is the best way to bring those pieces together. LONG Building Technologies works with architects, contractors, and project teams to identify architectural screening solutions that address project requirements without sacrificing the design vision. We also work with a variety of manufacturers who keep performance and serviceability in mind during the designs.
Explore our Architectural Screens page to learn more or contact our Architectural Solutions team to discuss your next project.