ARCHITECTURAL SCREENS & EQUIPMENT SCREEN WALLS

Conceal mechanical equipment, enhance building façades, and meet project-specific screening requirements with architectural screen systems designed around your building.

What Are Architectural Screens?

Equipment screen surrounding and obscuring rooftop HVAC equipment

Types of Architectural Screens

Equipment Screens

Equipment screens conceal HVAC units, generators, utilities, and other mechanical components that may otherwise be visible from streets, neighboring properties, or public areas. They can be installed at roof level or around equipment located elsewhere on the property.

A properly designed equipment screen must account for more than appearance. For HVAC applications in particular, designers need to consider airflow, equipment clearances, service access, roof conditions, and structural requirements. Screen configuration and mounting should therefore be coordinated with the equipment and project requirements rather than treated strictly as a decorative element.

Top view of commercial building with HVAC equipment screens surrounding top

Rooftop Screens

A rooftop screen is a type of equipment screening installed around mechanical systems located on the roof. Because rooftop screens are exposed to wind and weather, structural design is a critical consideration. Depending on the system, supports may connect to the building structure or another engineered support assembly. Screen height, attachment, panel openness, wind exposure, and building conditions can all affect the design.

The screening assembly also needs to work with the roof rather than compromise it. Waterproofing, penetrations, drainage, equipment access, and roof maintenance all need to be considered during system selection and detailing. However, it is possible for screens can be added to an existing building or on a project where they were forgotten, provided the roof structure allows for additional weight. Our team is highly experienced with non-penetrating screens, like products from our partners at LINEA, that are applied to buildings after the initial design.

Architectural Screen Walls

An architectural screen wall can extend across a larger portion of a rooftop, exterior wall, equipment area, or other building area requiring concealment. Depending on the design, these assemblies can blend into the surrounding architecture or become an intentional visual feature.

Screen walls may use:

  • Horizontal or vertical louvers
  • Perforated metal
  • Expanded metal
  • Solid or partially open metal panels
  • Custom patterns and decorative panels
  • A combination of materials or profiles
Tight-spaced louvers blocking rooftop equipment

Equipment screens conceal HVAC units, generators, utilities, and other mechanical components that may otherwise be visible from streets, neighboring That flexibility gives architects the ability to approach screening as part of the overall façade design rather than as an afterthought.

Patterned architectural screens applied to parking garage

Parking Garage Screening

Parking structures present a different screening challenge. They may require openness or ventilation while architects also want to reduce visibility into parked vehicles, ramps, lighting, or structural components.

Parking garage screening can help visually unify an otherwise open structure and give the garage a façade that complements adjacent buildings. Requirements vary significantly by project, particularly where ventilation, openings, fire protection, or local development standards apply.

Local requirements are especially important here. Zoning and development codes can differ by city and may contain separate provisions addressing screening of parking garages and screening of mechanical/utility equipment. It’s important to understand that there is no universal level and to work with an architectural solutions provider who can help navigate screening requirements at the municipal level.

Perforated Screen Systems

Perforated screen systems use panels with intentionally placed holes or slots across the material. Changing the opening size, shape, and spacing can affect both the appearance of the screen and how much air, light, and visibility can pass through it. Modifying the holes on the screen also allows for the creation of patterns or images, which can contribute to a unique visual look. This makes perforated metal particularly useful when a project needs to balance concealment with openness and aesthetics.

For example, a designer may select a denser perforation pattern when visual screening is the priority. A more open configuration may be appropriate when airflow is more important. This relationship should always be evaluated against the specific equipment, engineering requirements, and desired sightlines rather than relying on appearance alone.

Perforated white architectural screen over commercial building
Sound attenuating acoustic screen surround HVAC equipment

Acoustical Screens

Acoustical screens are architectural screening systems designed for sound attenuation and to help reduce noise from mechanical equipment while concealing it from view. They are commonly used around rooftop or ground-level HVAC equipment, generators, and other mechanical systems where sound may be a concern for occupants or neighboring properties.

Unlike standard architectural screens, which primarily address visibility and aesthetics, acoustical screens incorporate noise-control features, like sound block panels, as part of their design. The system must also be designed so that necessary airflow and equipment clearances are maintained, particularly around HVAC equipment. Because of these additional performance requirements, acoustical screens can be a good fit for projects where appearance, equipment operation, and noise control all need to be considered together.

Architectural Screens and Code Compliance

Screen selection is not solely an aesthetic decision.

The 2024 International Building Code (IBC) includes provisions specifically addressing mechanical equipment screens on rooftops. Section 1511.6 requires mechanical equipment screens to use materials appropriate to the building’s construction type and includes fire-resistance considerations based in part on fire separation distance. Additional provisions apply to screen height and materials for certain construction types.

As mentioned with parking garage screening, projects may also be subject to local zoning ordinances, development standards, design guidelines, or other requirements governing how rooftop mechanical equipment and parking structures are screened. Those requirements are jurisdiction-specific.

As a result, architects and contractors should evaluate issues such as:

  1. Local screening requirements: Determine whether mechanical equipment must be concealed from specified streets, properties, or viewing locations.
  2. Building and fire code: Confirm applicable requirements for the screen assembly, materials, height, and building construction type.
  3. Structural loads: Design supports and connections for the loads applicable to the project.
  4. HVAC operation: Maintain the clearances and airflow required by the equipment manufacturer and mechanical design.
  5. Maintenance access: Provide practical access for technicians to inspect, repair, and replace equipment.
  6. Roof conditions: Coordinate supports and penetrations with roofing, waterproofing, drainage, and the underlying structure.

Screens should therefore be coordinated early enough in design that architectural, structural, roofing, and mechanical requirements can be considered together to meet compliance.

Screens, Louvers, and Cladding: What's the Difference?

Architectural louvers use blades or slats and can perform functions including airflow, ventilation, weather protection, privacy screening, and noise control depending on the products. Architectural louvers are available in different materials, orientations, colors, finishes, and blade styles.

Wall cladding systems, by comparison, form a secondary exterior skin over the building’s primary wall and can provide aesthetic, weather-protection, and thermal-performance functions.

Find the Right Architectural Screen for Your Project

An effective screening system should do more than hide what’s behind it – it has to fit into the building’s architecture while accounting for structural conditions, equipment needs, accessibility, and project-specific code requirements.

Need an equipment screen, rooftop screen, parking garage screening system, or custom architectural screen wall? LONG’s Architectural Solutions team works with you throughout your full project, including budget planning, installation management, quality control, and warranty support.

Contact LONG to discuss the architectural, performance, and project requirements for your screen system.

t13473od

AARON OVERMAN | ACCOUNT EXECUTIVE

News & Knowledge Center